Printable Version
NEW TCS Command summary
Here are all commands of the NEW TCS. They can be abreviated as long as they are unique.
Note that the full reference is found in Extended description of Commands in the new TCS
Shortcuts:
-
- Critical Commands and Functions - Only directly on TCS Terminal
- Telescope
- Catalogue Handling
- Autoguider
- Active Optics
- Commands for terminal use only
Critical Commands and Functions - Only directly on TCS User Interface Terminal
Back to top
Commands marked with '*' can also be executed via a function key on the TCS keyboard - Consult the cookbook for further instructions.
- Open-Upper-Hatch (o-u-h) *
- Open upper dome hatch. (Check weather conditions first).
- Close-Upper-Hatch (c-u-h) *
- Close upper dome hatch.
- Stop-Upper-Hatch (s-u-h) *
- Stop upper dome hatch.
- Open-Lower-Hatch (o-l-h) *
- Open lower dome hatch.
- Close-Lower-Hatch (c-l-h) *
- Close lower dome hatch.
- Stop-Lower-Hatch (s-l-h) *
- Stop lower dome hatch.
- Open-Mirror-Covers (o-m-c) *
- Open mirror covers.
- Close-Mirror-Covers (c-m-c) *
- Close mirror covers.
- Stop-Mirror-Covers (s-m-c) *
- Stop mirror covers.
- Counter-Weights-Height
- Set counter weights height (Staff only!).
- Stop-Counter-Weights
- Stop counter weights (Staff only!).
- Power-On (po-on)
- Power on telescope.
- Power-Off (po-of)
- Power off telescope.
- TV-On
- Turn on guide camera.
- TV-Off (tv-of)
- Turn off guide camera.
- Keep-Telescope-Opened
- Allow extra open time at sunrise.
- Accept-Actual-Structure-Temperature
- If large temperature jumps of structure.
- Dust-Level-High
- Set dust flag to high (Staff only!).
- Dust-Level-Low
- Set dust flag to low (Staff only!).
- Change-Access-Code
- For setting to sequencer code or any code.
- Calibrate-TV-Focus_Zero_Point *
- Change auto TV focus parameter.
- Inhibit-Remote-Commands
- For personal and telescope safety (Staff only!).
- Permit-Remote-Commands
- Used after critical work (Staff only!).
- Load-Pointing-Model
- Load pointing model (Staff only!).
- Kill-Control-System
- Kills control system (Staff only!).
Telescope
Back to top
- Abort-Preset *
- Aborts Preset.
- ADC-Actual
- Sets the ADC for actual telescope position.
- ADC-Arm-In
- Moves the ADC into beam.
- ADC-Arm-Out
- Moves the ADC out of the beam.
- ADC-Explicit
- Sets the ADC prisms explicitly.
- ADC-Initialize-Prism-1
- Finds the internal reference.
- ADC-Initialize-Prism-2
- Finds the internal reference.
- ADC-Mode-Automatic-Continous
- Prisms will follow actual telescope positions.
- ADC-Mode-Automatic-Off
- Prisms will move only if told so.
- ADC-Mode-Automatic-When-Presetting
- Prisms will move only at presets to the commanded telescope position.
- Altitude-Position
- Altitude position value.
- Automatic-TV-Focus
- Sets TV focus at presets from telescope focus.
- Azimuth-Position
- Azimuth position value.
- Baffle-Lamp-1-On
- Calibration lamp on mirror covers.
- Baffle-Lamp-1-Off
- Calibration lamp on mirror covers.
- Baffle-Lamp-2-On
- Calibration lamp on mirror covers.
- Baffle-Lamp-2-Off
- Calibration lamp on mirror covers.
- Baffle-Lamp-3-On
- Calibration lamp on mirror covers.
- Baffle-Lamp-3-Off
- Calibration lamp on mirror covers.
- Building-Hoist-Position *
- Move building to hoist position.
- Building-Park-Position *
- Move building to park position.
- Camera-Probe-CCD
- Pickup mirror for StanCam into the beam.
- Camera-Probe-FIES
- Pickup mirror for FIES into the beam, alias for camera-probe-split.
- Camera-Probe-Park
- Pickup mirrors out of the beam.
- Camera-Probe-Split
- Pickup mirror for FIES into the beam.
- CCD-Filter
- StanCam filter.
- DEC-Delta
- DEC delta. *
- Equatorial-Offset
- Equatorial offset.
- Field-Rotation
- Set field rotation.
- Field-Delta-Rotation
- Add to field rotation.
- Focus-Delta
- Set focus offset for filter.
- Focus-Position
- Set telescope focus.
- Get-Guide-Star *
- Get guide star.
- Guide-Probe-Center
- Guide probe in center.
- Guide-Probe-Park
- Guide probe in park position.
- Guide-Probe-Position
- Set guide probe position.
- Guide-Star-Automatic
- Automatic guide star acquisition.
- Guide-Star-Manual
- Manual guide star acquisition.
- Horisontal-Offset
- Offset in Azimuth and Altitude.
- Idle-Mode
- Same as Abort-Preset.
- Initialize-TV-Filter
- For non-cooperative filter wheel drive.
- Instrument-Name
- Set actual instrument name and preferred guide star field.
- Instrument-Parallactic-Angle
- Parallactic angle for instrument.
- Manual-TV-Focus
- TV focus only by manual setting.
- Name-CCD-Filter
- Name StanCam filter.
- New-Object
- Do not insert new object into catalogue, just go to it.
- Offset-Mode
- Offset mode.
- Offset-Size
- Offset size.
- Permanent-Offset-Adopt
- Adopt permanent offset - compensates for pointing errors.
- Permanent-Offset-Reset
- Reset permanent offset.
- Probe-Step-Size
- Set guide probe step size.
- RA-Delta
- RA Delta. *
- Rotator-Automatic
- Rotator keeps current field rotation.
- Rotator-Manual
- Rotator manual.
- Rotator-Position
- Rotator Position.
- Rotator-Turn-360
- Rotator turns 360 degrees.
- Set-Rate
- Set rate.
- Show-Page
- Show page. *
- Store-Pointing-Data
- Start tracking.
- Tracking-On
- Start tracking.
- TV-filter
- Filter for guide probe TV camera.
- TV-Focus
- Set guide TV focus. *
- X
- Set guide probe x-position.
- Y
- Set guide probe y-position.
- Zenith
- Point telescope to zenith (park position). *
Catalogue Handling
Back to top
- Append-Object
- Append new object to end of catalogue.
- Delete-Selected-Object
- Delete object from catalogue.
- Enter-Object
- Add new object to catalogue. *
- Erase-Catalogue
- Erase current catalogue.
- Find-Object
- Searches the current catalogue from first entry, if not found then searches standard catalogues for a match, if found there then inserts the matching object into the current catalogue.
- Goto-Object
- First does a find object as described above, then presets to the object if found.
- Insert-Actual-Position
- Add current position to catalogue. *
- Insert-Nearest-FK5
- Add nearest FK5 star to catalogue. *
- List-Catalogue-Errors
- List errors in catalogue.
- Local-Read-Catalogue
- Read catalogue from the local TCS disc.
- Local-Store-Catalogue
- Store the actual catalogue on the local TCS disc.
- Preset-To-Selected
- Preset to selected object coordinates with current field rotation. *
- Preset-With-Parallactic-Angle-To-Selected
- Preset to selected object coordinates with parallactic angle. *
- Read-Catalogue
- Read catalogue into TCS.
- Select-Next-Object
- Select next object in catalogue. *
- Select-Previous-Object
- Select previous object in catalogue. *
- Sort-Catalogue
- Sorts the objects in the current catalogue after the specified item like Name, RA, DEC etc..
- Store-Catalogue
- Store the actual catalogue.
Autoguider
Back to top
- 0
- Do not move any of the suggested stars to center of star box (in auto positioning).
- 1
- Move suggested star number 1 to center of star box (in auto positioning).
- 2
- Move suggested star number 2 to center of star box (in auto positioning).
- 3
- Move suggested star number 3 to center of star box (in auto positioning).
- Auto-Positioning-Off
- Put guide star in the star box the traditional manual way.
- Auto-Positioning-Semi
- At a preset, up to 3 guide stars are searched for and marked on autoguider screen, user chooses one of them.
- Auto-Positioning-Full
- Places star box at center, then not moved. At a preset, guide star is (as far as possible) automatically placed in the star box wherever the box is and autoguiding switched on.
- Auto-Positioning-Retry
- Try again.
- Background-Box-Position
- Position for sky box on guide monitor.
- Background-Box-Quadrant-Size
- Size of sky box on guide monitor.
- Box-At-Center
- Guide probe box to center of guide monitor.
- Box-Motion-Start
- Star box motion start.
- Box-Motion-Stop
- Star box motion stop.
- Ag-Off
- Stop autoguiding.
- Ag-On
- Start autoguiding.
- Ag-Relaxed-On
- Start relaxed autoguiding (move guide box to star).
- Star-Box-Position
- Position of auto-guider box.
- Star-Box-Quadrant-Size
- Size of auto-guider box.
Active Optics
Back to top
- Active-Optics-Off
- Switch off active optics.
- Active-Optics-On
- Switch on active optics.
- Copy-EngZ-To-AlternateZ
- Copy EngZ To AlternateZ.
- Copy-WFSz-To-AlternateZ
- Copy WFSz To AlternateZ.
- Use-Alternate-Zernike
- Use alternative zernike.
- Use-WFS-Zernike
- Use WFS zernike.
- Zernike-Tables-Off
- Zernike tables off.
- Zernike-Tables-On
- Zernike tables on.
Commands for terminal use only
Back to top
- Show-Page
- Show page. *
- Status-Menu
- Show status menu. *
- Catalogue-Menu
- Shows catalogue menu. *
- Log-Menu
- Shows log menu. *
- Refresh-Screen
- Refresh TCS screen.
- Access-Code
- For remote terminal users.
- UI-Exit
- UI exit (On control room UI terminal only after explicit permission from staff).
Latest update: IS 2012-03-18 Fully up-to-date.
|