In Table 2 the number of faults and total time lost as a function of the system and kind of fault is presented together with the overall numbers for the previous two periods (48 and 49).



Table 2: Down-time statistics for period 50$^a$
Syst/Type Soft Elec Optics Mech Others Total P49/P48
Telescope 2 00:20 1 00:00 0   4 09:00 1 01:30 8 10:50 14/10 01:45/00:50
Building 0   1 00:00 0   4 00:00 2 00:00 7 00:00 3/1 00:00/00:00
Computers 10 00:35 2 00:00 0   0   2 00:00 14 00:35 11/8 00:35/00:30
ALFOSC 36 00:45 2 00:00 1 00:00 0   0   39 00:45 23/25 01:40/05:05
MOSCA 0   0   0   0   0   0   3/5 00:00/01:00
NOTCam 6 00:00 2 00:00 0   2 00:15 0   10 00:15 2/3 00:00/00:00
StanCam 5 01:30 0   0   0   0   5 01:30 3/0 00:15/00:00
FIES 12 02:55 0   0   0   1 00:00 13 02:55 3/9 00:00/00:00
Others 3 00:00 0   0   1 00:00 1 00:00 5 00:00 6/4 00:10/00:00
Total 74 06:05 8 00:00 1 00:00 11 09:15 7 01:30 101 16:50 68/65 04:25/07:30
P49 43 02:45 12 00:40 1 00:15 6 00:30 6 00:15 68 04:25    
P48 42 04:55 10 01:30 1 00:00 7 00:45 5 00:20 65 07:30    
$^a$For each system-type category the total number of faults and total time lost are given